Separate general and critical requirements
A drawing needs a clear baseline for ordinary dimensions and explicit controls for critical features. Avoid applying the tightest tolerance to every feature by default.
- State units and the governing general-tolerance standard or title-block rule.
- Call out critical sizes and geometric relationships individually.
- Use reference dimensions only for information, not acceptance.
- Check for duplicated or conflicting controls.